Analysis of the Efficiency of Landfill Gas Treatment for Power Generation in a Cogeneration System in Terms of the European Green Deal

Pokaż uproszczony rekord

dc.contributor.author Ciuła, Józef
dc.contributor.author Generowicz, Agnieszka
dc.contributor.author Gronba-Chyła, Anna
dc.contributor.author Wiewiórska, Iwona
dc.contributor.author Kwaśnicki, Paweł
dc.contributor.author Cygnar, Mariusz
dc.date.accessioned 2024-03-05T08:31:39Z
dc.date.available 2024-03-05T08:31:39Z
dc.date.issued 2024
dc.identifier.citation Ciuła, J.; Generowicz, A.; Gronba-Chyła, A.; Wiewiórska, I.; Kwa´snicki, P.; Cygnar, M. Analysis of the Efficiency of Landfill Gas Treatment for Power Generation in a Cogeneration System in Terms of the European Green Deal. Sustainability 2024, 16, 1479. https://doi.org/ 10.3390/su16041479 pl_PL
dc.identifier.issn 2071-1050
dc.identifier.uri http://195.117.226.27:8080/xmlui/handle/123456789/650
dc.description.abstract Climate change and environmental degradation pose a threat to Europe and the world. The mechanism that will address these challenges is the European Green Deal, which envisions transforming the EU into a modern, resourceful, economical and competitive economy, aiming for zero greenhouse gas emissions. Landfill gas generated in a landfill waste deposit poses a threat to the environment and people. In this aspect, its capture, treatment and safe neutralization or use for energy purposes are important. Treatment of landfill gas, which is the fuel for gas engines in cogeneration units, is crucial for their proper operation and the quantity and quality of electricity and heat generated. The purpose of this study was to perform research to determine the hydrogen sulfide content of landfill gas and the actual efficiency of hydrogen sulfide removal from the gas using activated carbon. The tests performed constitute the basis for the reliable operation of gas engines in cogeneration installations and are dedicated mainly to the operators of these installations. Accordingly, three measurement campaigns were carried out, each with 42 measurements, the first for the “raw” gas obtained directly from the landfill, the second for the gas before entering the carbon filter and the third after its treatment. In addition, surface analysis was performed, and the elemental composition of the “fresh” molded activated carbon constituting the filter material was determined using a scanning electron microscope with an EDS system. The results showed a high elemental content of carbon in the test sample at 92.78%, while the efficiency of hydrogen sulfide removal from landfill gas by activated carbon, calculated from the measurements, was 97.05%. The obtained test results confirmed the validity of using impregnated activated carbon to remove hydrogen sulfide from landfill gas and its high adsorption efficiency, which can consequently result in reliable operation of the gas engine in the cogeneration unit and ultimately fit in with the objectives of the European Green Deal. The research results are an incentive for operators of cogeneration installations to systematically examine the quality of landfill gas and the efficiency of biogas purification devices. pl_PL
dc.language.iso en pl_PL
dc.publisher MDPI pl_PL
dc.rights Uznanie autorstwa 4.0 Międzynarodowe (CC BY 4.0)
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.pl
dc.subject landfill gas pl_PL
dc.subject biogas treatment pl_PL
dc.subject activated carbon pl_PL
dc.subject hydrogen sulfide pl_PL
dc.subject cogeneration pl_PL
dc.subject European Green Deal pl_PL
dc.title Analysis of the Efficiency of Landfill Gas Treatment for Power Generation in a Cogeneration System in Terms of the European Green Deal pl_PL
dc.type Article pl_PL