Streszczenie:
This work focused on the verification of the electrical parameters and the durability of
side connectors installed in glass–glass photovoltaic modules. Ensuring the safe use of photovoltaic
modules is achieved, among others, by using electrical connectors connecting the PV cell circuit
inside the laminate with an external electric cable. In most of the cases for standard PV modules, the
electrical connector in the form of a junction box is attached from the back side of the PV module.
The junction box is glued to the module surface with silicone where the busbars were previously
brought out of the laminate through specially prepared holes. An alternative method is to place
connectors on the edge of the module, laminating part of it. In such a case, the specially prepared
“wings” of the connector are tightly and permanently connected using laminating foil, between
two glass panes protecting against an electrical breakdown. Additionally, this approach eliminates
the process of preparing holes on the back side of the module, which is especially complicated and
time-consuming in the case of glass–glass modules. Moreover, side connectors are desirable in BIPV
applications because they allow for a more flexible design of installations on façades and walls of
buildings. A series of samples were prepared in the form of PV G-G modules with side connectors,
which were then subjected to testing the connectors for the influence of environmental conditions.
All samples were characterized before and after the effect of environmental conditions according
to PN-EN-61215-2 standards. Insulation resistance tests were performed in dry and wet conditions,
ensuring full contact of the tested sample with water. For all modules, before being placed in the
climatic chamber, the resistance values were far above the minimum value required by the standards,
allowing the module to be safely used. For the dry tests, the resistance values were in the range of GΩ,
while for the wet tests, the obtained values were in the range of MΩ. In further work, the modules
were subjected to environmental influences in accordance with MQT-11, MQT-12, and MQT-13 and
then subjected to electrical measurements again. A simulation of the impact of changing climatic
conditions on the module test showed that the insulation resistance value is reduced by an order of
magnitude for both the dry and wet tests. Additionally, one can observe visual changes where the
lamination foil is in contact with the connector. The measurements carried out in this work show the potential of side connectors and their advantage over rear junction boxes, but also the technological
challenges that need to be overcome.