Repozytorium Instytucjonalne

Akademii Nauk Stosowanych

w Nowym Sączu

Analysis of Energy Generation Efficiency and Reliability of a Cogeneration Unit Powered by Biogas

Pokaż uproszczony rekord

dc.contributor.author Ciuła, Józef
dc.contributor.author Kowalski, Sławomir
dc.contributor.author Generowicz, Agnieszka
dc.contributor.author Barbusiński, Krzysztof
dc.contributor.author Matuszak, Zbigniew
dc.contributor.author Gaska, Krzysztof
dc.date.accessioned 2023-06-23T12:44:14Z
dc.date.available 2023-06-23T12:44:14Z
dc.date.issued 2023
dc.identifier.citation Ciuła J, Kowalski S, Generowicz A, Barbusiński K, Matuszak Z, Gaska K. Analysis of Energy Generation Efficiency and Reliability of a Cogeneration Unit Powered by Biogas. Energies. 2023; 16(5):2180. https://doi.org/10.3390/en16052180 pl_PL
dc.identifier.issn 1996-1073
dc.identifier.uri http://195.117.226.27:8080/xmlui/handle/123456789/488
dc.description.abstract Landfill gas recovery and utilisation is a solution which reduces the adverse environmental impact of the landfill. Combined heat and power (CHP) generation improves the energy balance of the facility and enables the optimal management of energy generated from a renewable source. This article aims to analyse the operation of the CHP unit in two aspects, that is, in terms of energy generation efficiency and operational availability. Energy ratios were calculated and the analysis was based on the Weibull distribution in order to assess the CHP unit’s operational reliability to minimise costs and maximise energy production. The results of the investigations and analyses demonstrated an increase of the gas yield by 29.5%, an increase of energy production by approx. 42%, and the reduction of downtime by 28.2% from 2018 to 2022. Studies related to the efficiency and reliability of operation of the cogeneration unit showed an increase in all the main parameters analysed, which resulted in greater energy and operational efficiency. The research which has been conducted is a significant scientific contribution to the optimisation of the “waste-to-energy” process for cogeneration units with the capacity of up to 0.5 MW. pl_PL
dc.language.iso en pl_PL
dc.publisher MDPI pl_PL
dc.rights Uznanie autorstwa 4.0 Międzynarodowe (CC BY 4.0)
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.pl
dc.subject biogas cogeneration system pl_PL
dc.subject landfill gas pl_PL
dc.subject reliability pl_PL
dc.subject Weibull distribution pl_PL
dc.title Analysis of Energy Generation Efficiency and Reliability of a Cogeneration Unit Powered by Biogas pl_PL
dc.type Article pl_PL


Pliki tej pozycji

Pozycja umieszczona jest w następujących kolekcjach

Pokaż uproszczony rekord

Uznanie autorstwa 4.0 Międzynarodowe (CC BY 4.0) Poza zaznaczonymi wyjątkami, licencja tej pozycji opisana jest jako Uznanie autorstwa 4.0 Międzynarodowe (CC BY 4.0)